Aspects on testing in laboratory conditions of an electromagnetic pulsator

Show simple item record

dc.contributor.author Chirilă, Constantin
dc.date.accessioned 2021-04-27T08:31:23Z
dc.date.available 2021-04-27T08:31:23Z
dc.date.issued 2020
dc.identifier.citation Chirila, C. 2020. "Aspects on testing in laboratory conditions of an electromagnetic pulsator". Lucrări Științifice USAMV - Iași Seria Zootehnie 73(25): 119-123.
dc.identifier.uri https://repository.iuls.ro/xmlui/handle/20.500.12811/994
dc.description.abstract The efficient operation of the mechanical milking operation in the milking rooms, implies the use of pulsers, which allow to change the ratio between the extraction phase and the massage phase and even the working frequency, during operation. These requirements are fully met by the electromagnetic pulsators. The operating organs of these pulsators are actuated by means of electric coils controlled by an electrical circuit. In this way, through the electrical control, various values of the working frequency and different ratios between the extraction and massage time can be achieved. In practice, certain values for the working frequency and certain values for the extraction-massage ratio are accepted at national and European level. Based on these considerations, the author presents in the present paper the results of laboratorytests performed with an electromagnetic type pulsator of his own conception. The tested pulsator allows the production of two different working ratios (extraction time / massage time), namely: 3: 1 and 1.1, at a frequency of 60 pulses / minute. The switching from one working mode to another is controlled by the milk flow coming out of the milk collector. Following the tests performed for various values of the vacuum in the installation, it was observed that the working frequency of the electromagnetic pulsator to be tested remains constant. This parameter is within the normal operating limits of 50 ... 60 +/- 3 pulses / min. Also, the ratios between the extraction time and the massage time are within the usual values en_US
dc.language.iso en en_US
dc.publisher “Ion Ionescu de la Brad” University of Agricultural Sciences and Veterinary Medicine, Iaşi en_US
dc.rights Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)
dc.rights.uri https://creativecommons.org/licenses/by-nc-sa/4.0/deed.en
dc.subject pulsator en_US
dc.subject milk equipement en_US
dc.title Aspects on testing in laboratory conditions of an electromagnetic pulsator en_US
dc.type Article en_US
dc.author.affiliation C. Chirila, University of Agricultural Sciences and Veterinary Medicine Iasi, Romania
dc.publicationName Lucrări Științifice Seria Zootehnie - USAMV Iași
dc.publicationName Scientific Papers Animal Sciences USAMV Iași
dc.volume 73(25)
dc.publicationDate 2020
dc.startingPage 119
dc.endingPage 123
dc.identifier.eissn 2067-2330


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)